Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 73.224
Filter
2.
PLoS One ; 19(5): e0301581, 2024.
Article in English | MEDLINE | ID: mdl-38768168

ABSTRACT

Research is ongoing to find solutions to the problem of Consolidation and seepage in saturated clay in enclosure space. Firstly, the boundary of non-zero-constant values is established, considering the seepage boundary of the clay is affected by pumping water or lowering boundary pressure on the site. Secondly, the differential equation is established to reflect the spatial and temporal variations of excess pore water pressure dissipation in the clay in enclosure space, and the solution is derived using variable separation methods. Finally, based on results of the solution derived, contour maps of the water pressure are drawn corresponding with the different inhomogeneous boundary conditions.


Subject(s)
Clay , Clay/chemistry , Water/chemistry , Pressure , Models, Theoretical , Aluminum Silicates/chemistry , Solutions
3.
World J Urol ; 42(1): 331, 2024 May 17.
Article in English | MEDLINE | ID: mdl-38758400

ABSTRACT

PURPOSE: To investigate fluid absorption and its influencing factors during flexible ureteroscopy with intelligent control of renal pelvic pressure (RPP). METHODS: A total of 80 patients with upper urinary tract calculi underwent flexible ureteroscopy with intelligent control of RPP by pressure-measuring ureteral access sheath and were randomly divided into four groups. The RPP of Groups A, B, and C were set at - 5, 0 and 5 mmHg, respectively. Conventional flexible ureteroscopy with uncontrolled pressure served as control Group D. The perfusion flow rate was set at 100 ml/min in the four groups, with 20 patients in each group. The fluid absorption was measured by 1% ethanol every 10 min. Operation time, stone-free rate, and complications were recorded. RESULT: Seventy-three patients were finally included in the RCT. The general and preoperative data of the patients were comparable between the groups. The fluid absorption of Groups A, B, and C was significantly less than that of Group D (P < 0.01). Fluid absorption and operation time were positively correlated, and the correlation coefficients R were 0.864, 0.896, 0.918, and 0.947, respectively (P < 0.01). The fluid absorption of patients with vomiting, fever and ureteral injury was greater than that of patients without complications in the four groups (P < 0.01). In different groups, fluid absorption was greater in patients with ureteral injury Post-Ureteroscopic Lesion Scale (PULS) 1-3 than in noninjured patients (P < 0.01). CONCLUSION: Flexible ureteroscopy with intelligent control of RPP effectively reduces the absorption of perfusion fluid. Operation time and ureteral injury are also key factors affecting perfusion fluid absorption. REGISTRATION NUMBER AND DATE: NCT05201599; August 11, 2021.


Subject(s)
Kidney Calculi , Kidney Pelvis , Pressure , Ureteroscopes , Ureteroscopy , Humans , Ureteroscopy/methods , Female , Kidney Pelvis/surgery , Male , Middle Aged , Adult , Kidney Calculi/surgery , Aged
4.
PLoS One ; 19(5): e0301204, 2024.
Article in English | MEDLINE | ID: mdl-38728281

ABSTRACT

Tidal bore impact can be strong and destructive, placing estuarine infrastructures under great threat. However, there is a lack of research focusing on accurately estimating the impact pressure exerted by tidal bores. Herein new experiments were conducted to investigate the pressure of tidal bore fronts in a glass flume. Through analysis of instantaneous pressure of three forms of tidal bore, it was observed that the pressure fluctuation of weak and strong breaking bore fronts is characterized by impact pressure. The vertical distribution and maximum impact pressure of tidal bore were studied.The maximum impact pressure of breaking bore fronts appeared around 0.46 times height of it. The relationship between relative impact pressure and height of the tidal bore fronts was found to closely follow a normal probability density function. Through nonlinear regression analysis, an empirical equation was derived to calculate impact pressure, which was validated using observation data from the Qiantang River in China. This equation can be utilized to predict the impact pressure of tidal bore fronts and provide valuable support for estuarine engineering design.


Subject(s)
Pressure , China , Tidal Waves , Rivers , Estuaries , Models, Theoretical
5.
PLoS One ; 19(5): e0300241, 2024.
Article in English | MEDLINE | ID: mdl-38696384

ABSTRACT

OBJECTIVE: Technical ex-vivo comparison of commercial nebulizer nozzles used for Pressurized Intraperitoneal Aerosol Chemotherapy (PIPAC). METHODS: The performance of four different commercial nebulizer nozzles (Nebulizer; HurriChemTM; MCR-4 TOPOL®; QuattroJet) was analysed concerning: i) technical design and principle of operation, ii) operational pressure as function of the liquid flow rate, iii) droplet size distribution via laser diffraction spectrometry, iv) spray cone angle, spray cone form as well as horizontal drug deposition by image-metric analyses and v) chemical resistance via exposing to a cytostatic solution and chemical composition by means of spark optical emission spectral analysis. RESULTS: The Nebulizer shows quasi an identical technical design and thus also a similar performance (e.g., mass median droplet size of 29 µm) as the original PIPAC nozzles (MIP/ CapnoPen). All other nozzles show more or less a performance deviation to the original PIPAC nozzles. The HurriChemTM has a similar design and principle of operation as the Nebulizer, but provides a finer aerosol (22 µm). The principle of operation of MCR-4 TOPOL® and QuattroJet differ significantly from that of the original PIPAC nozzle technology. The MCR-4 TOPOL® offers a hollow spray cone with significantly larger droplets (50 µm) than the original PIPAC nozzles. The QuattroJet generates an aerosol (22 µm) similar to that of the HurriChemTM but with improved spatial drug distribution. CONCLUSION: The availability of new PIPAC nozzles is encouraging but can also have a negative impact if their performance and efficacy is unknown. It is recommended that PIPAC nozzles that deviate from the current standard should be subject to bioequivalence testing and implementation in accordance with the IDEAL-D framework prior to routine clinical use.


Subject(s)
Aerosols , Nebulizers and Vaporizers , Humans , Antineoplastic Agents/administration & dosage , Pressure , Particle Size , Equipment Design
6.
Scand Cardiovasc J ; 58(1): 2347295, 2024 Dec.
Article in English | MEDLINE | ID: mdl-38706409

ABSTRACT

Objectives. This study investigated the influence of higher pressure protection with a small diameter balloon of side branch (SB) on bifurcation lesions. Background. Of the different coronary stent implantation techniques, the modified jailed balloon technique has become a viable option for bifurcation lesions. However, there was no detailed study on the relationship between the balloon inflation pressure of the main vessel (MV) and SB. Methods. In this study, we collected information of patients who underwent percutaneous coronary intervention (PCI) for bifurcated lesions between March 2019 and December 2022. They were divided into two groups according to the operation way: active jailed balloon technique (A-JBT) group and jailed wire technique (JWT) group. Results. A total of 216 patients were enrolled. The A-JBT group had a larger SB stenosis diameter (1.53 ± 0.69 vs. 0.95 ± 0.52, p < .001), the lower degree of stenosis (44.34 ± 18.30 vs. 63.69 ± 17.34, p < .001) compared to the JWT group. However, the JWT group had a higher incidence of SB occlusion (18.0% vs. 1.9%, p < .001) compared to the A-JBT group. Nevertheless, the success rate for both groups was 100%. Conclusions. This novel high inflation pressure and small diameter balloon approach we propose has significant advantages. There is a lower rate of SB occlusion and SB dissection, which is more cost-effective and provides better clinical outcomes for the patient. This method should be considered in the future for treating bifurcation lesions.


Subject(s)
Angioplasty, Balloon, Coronary , Cardiac Catheters , Coronary Artery Disease , Humans , Male , Female , Aged , Middle Aged , Treatment Outcome , Coronary Artery Disease/therapy , Coronary Artery Disease/diagnostic imaging , Angioplasty, Balloon, Coronary/instrumentation , Angioplasty, Balloon, Coronary/adverse effects , Retrospective Studies , Stents , Coronary Stenosis/diagnostic imaging , Coronary Stenosis/therapy , Coronary Stenosis/surgery , Risk Factors , Pressure , Time Factors , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/instrumentation
7.
Sci Rep ; 14(1): 11504, 2024 05 20.
Article in English | MEDLINE | ID: mdl-38769360

ABSTRACT

Pressure drifting is a troublesome error in invasive coronary function tests. This study aimed to evaluate the relationship between prolonged and short-time pressure equalizations in pressure drifting. Pressure drifting was defined as the pressure gradient between the mean pressure of the distal wire sensor (Pd) and aortic pressure (Pa) when the wire was withdrawn to the tip of the guiding catheter. Significant drifts 1 and 2 were defined as the absolute values of pressure gradients > 2 and > 3 mmHg, respectively. A logistic regression model was used to evaluate the associations between prolonged pressure equalization and each pressure drifting. The prolonged pressure equalization strategy was associated with a lower incidence of drift 1 than the short-time pressure equalization strategy (6.84% vs. 16.92%, p < 0.05). However, no statistical differences were found in the incidence of drift 2 between the prolonged and short-time pressure equalization strategies (4.27% vs. 7.69%, p = 0.34). In the multivariable regression model, only the prolonged pressure equalization strategy predicted a lower incidence of pressure drift 1. In conclusion, the prolonged pressure equalization strategy was associated with a lower incidence of significant pressure drifting with more stringent thresholds than the short-time pressure equalization strategy.


Subject(s)
Cardiac Catheterization , Humans , Male , Female , Aged , Middle Aged , Cardiac Catheterization/methods , Pressure , Blood Pressure/physiology
8.
Acta Ortop Mex ; 38(2): 101-104, 2024.
Article in Spanish | MEDLINE | ID: mdl-38782475

ABSTRACT

INTRODUCTION: it is estimated that 302 million people worldwide are affected by osteoarthritis, corresponding to 60% osteoarthritis (OA) of the knee, which responsible 80% of disability in older adults, hence the importance of the association of the sign with the early inflammatory process in OA. OBJECTIVE: to determine the association of digital pressure sign in patients with and without osteoarthritis of the knee. MATERIAL AND METHODS: this was an observational, comparative cross-sectional study, carried out in patients with and without a diagnosis of knee OA, to whom the digital pressure sign was determined. The sample was calculated with the formula for two proportions, obtaining a total of 40 participants per group, obtained by non-probabilistic sampling for convenience. The statistical analysis included frequencies, percentages, 2 and OR. The bioethics regulations in force were respected. RESULTS: the study included 80 participants, with a median age of 48.9 years (RQI 46-53.7), 73.1% were predominantly female sex (38), and a statistically significant association was found between patients with OA and the presence of digital pressure sign, 2 4.62 and p value = 0.41, OR of 2.65. CONCLUSIONS: the presence of digital pressure sign increases the probability of having OA 2.65 times more.


INTRODUCCIÓN: se estima que 302 millones de personas en el mundo son afectadas por osteoartritis, correspondiendo 60% a osteoartritis (OA) de rodilla, causante de 80% de discapacidad en adultos mayores, de ahí la importancia de la asociación del signo de digito-presión con el proceso inflamatorio temprano en OA. OBJETIVO: determinar la asociación del signo de digito-presión en pacientes con y sin osteoartritis de rodilla. MATERIAL Y MÉTODOS: estudio observacional, transversal comparativo, realizado en pacientes con y sin diagnóstico de OA de rodilla, a quienes se les determinó el signo de digito-presión; la muestra se calculó con la fórmula para dos proporciones que determinó un total de 40 participantes por grupo, obtenidos por muestreo no probabilístico por conveniencia; el análisis estadístico incluyó frecuencias, porcentajes, 2 y OR. Se respetó la reglamentación de bioética vigente. RESULTADOS: el estudio incluyó a 80 participantes, con una mediana de edad de 48.9 años (RIQ 46-53.7), predominó el sexo femenino en 73.1% (38). Se encontró asociación estadísticamente significativa entre pacientes con OA y la presencia del signo de digito-presión, 2 4.62 y p = 0.41, OR de 2.65. CONCLUSIONES: la presencia del signo de digito-presión aumenta 2.65 veces más la probabilidad de tener OA.


Subject(s)
Osteoarthritis, Knee , Pressure , Humans , Female , Cross-Sectional Studies , Male , Osteoarthritis, Knee/pathology , Middle Aged , Fingers , Aged
9.
ACS Sens ; 9(5): 2575-2584, 2024 May 24.
Article in English | MEDLINE | ID: mdl-38695880

ABSTRACT

Although electronic textiles that can detect external stimuli show great promise for fire rescue, existing firefighting clothing is still scarce for simultaneously integrating reliable early fire warning and real-time motion sensing, hardly providing intelligent personal protection under complex high-temperature conditions. Herein, we introduce an "all-in-one" hierarchically sandwiched fabric (HSF) sensor with a simultaneous temperature and pressure stimulus response for developing intelligent personal protection. A cross-arranged structure design has been proposed to tackle the serious mutual interference challenge during multimode sensing using two separate sets of core-sheath composite yarns and arrayed graphene-coated aerogels. The functional design of the HSF sensor not only possesses wide-range temperature sensing from 25 to 400 °C without pressure disturbance but also enables highly sensitive pressure response with good thermal adaptability (up to 400 °C) and wide pressure detection range (up to 120 kPa). As a proof of concept, we integrate large-scalable HSF sensors onto conventional firefighting clothing for passive/active fire warning and also detecting spatial pressure and temperature distribution when a firefighter is exposed to high-temperature flames, which may provide a useful design strategy for the application of intelligent firefighting protective clothing.


Subject(s)
Pressure , Temperature , Textiles , Textiles/analysis , Humans , Fires , Firefighters , Protective Clothing , Graphite/chemistry , Wearable Electronic Devices
10.
J Med Internet Res ; 26: e44948, 2024 May 08.
Article in English | MEDLINE | ID: mdl-38718385

ABSTRACT

BACKGROUND: Monitoring of gait patterns by insoles is popular to study behavior and activity in the daily life of people and throughout the rehabilitation process of patients. Live data analyses may improve personalized prevention and treatment regimens, as well as rehabilitation. The M-shaped plantar pressure curve during the stance phase is mainly defined by the loading and unloading slope, 2 maxima, 1 minimum, as well as the force during defined periods. When monitoring gait continuously, walking uphill or downhill could affect this curve in characteristic ways. OBJECTIVE: For walking on a slope, typical changes in the stance phase curve measured by insoles were hypothesized. METHODS: In total, 40 healthy participants of both sexes were fitted with individually calibrated insoles with 16 pressure sensors each and a recording frequency of 100 Hz. Participants walked on a treadmill at 4 km/h for 1 minute in each of the following slopes: -20%, -15%, -10%, -5%, 0%, 5%, 10%, 15%, and 20%. Raw data were exported for analyses. A custom-developed data platform was used for data processing and parameter calculation, including step detection, data transformation, and normalization for time by natural cubic spline interpolation and force (proportion of body weight). To identify the time-axis positions of the desired maxima and minimum among the available extremum candidates in each step, a Gaussian filter was applied (σ=3, kernel size 7). Inconclusive extremum candidates were further processed by screening for time plausibility, maximum or minimum pool filtering, and monotony. Several parameters that describe the curve trajectory were computed for each step. The normal distribution of data was tested by the Kolmogorov-Smirnov and Shapiro-Wilk tests. RESULTS: Data were normally distributed. An analysis of variance with the gait parameters as dependent and slope as independent variables revealed significant changes related to the slope for the following parameters of the stance phase curve: the mean force during loading and unloading, the 2 maxima and the minimum, as well as the loading and unloading slope (all P<.001). A simultaneous increase in the loading slope, the first maximum and the mean loading force combined with a decrease in the mean unloading force, the second maximum, and the unloading slope is characteristic for downhill walking. The opposite represents uphill walking. The minimum had its peak at horizontal walking and values dropped when walking uphill and downhill alike. It is therefore not a suitable parameter to distinguish between uphill and downhill walking. CONCLUSIONS: While patient-related factors, such as anthropometrics, injury, or disease shape the stance phase curve on a longer-term scale, walking on slopes leads to temporary and characteristic short-term changes in the curve trajectory.


Subject(s)
Foot , Gait , Pressure , Walking , Humans , Male , Female , Cross-Sectional Studies , Walking/physiology , Adult , Foot/physiology , Gait/physiology , Young Adult , Biomechanical Phenomena
11.
Age Ageing ; 53(5)2024 May 01.
Article in English | MEDLINE | ID: mdl-38776215

ABSTRACT

BACKGROUND: Pain sensitivity varies across multimodal somatosensory stimuli that can rely on different conductive fibres, which, when damaged, will lead to neuropathies. However, there is limited research examining the characteristics of perceived pain, particularly as affected by the ageing process, as induced by various somatosensory stimuli that may rely on small or large fibres. METHODS: Using heat and pressure stimuli on small and large fibres separately on both younger and older adults, this study examined age-associated changes in pain perception by measuring self-reported pain sensitivity, pain threshold and pain discriminability. RESULTS: Heat pain threshold was significantly positively correlated with age, but not pressure pain threshold. Pain threshold increased and pain discriminability decreased in response to heat stimuli in the older participants compared with the younger ones. CONCLUSION: An age-associated decline in heat pain perception was observed, suggesting an earlier degradation of heat perception. These findings provide new insight into understanding and assessing somatosensory disorders, which can help ageing populations better maintain healthy sensory functioning.


Subject(s)
Aging , Hot Temperature , Pain Measurement , Pain Perception , Pain Threshold , Humans , Aged , Male , Female , Aging/psychology , Aging/physiology , Age Factors , Adult , Hot Temperature/adverse effects , Pain Measurement/methods , Young Adult , Middle Aged , Pressure , Aged, 80 and over
12.
Int J Mol Sci ; 25(9)2024 Apr 24.
Article in English | MEDLINE | ID: mdl-38731845

ABSTRACT

Moringa oleifera leaves are rich sources of bioactive compounds with potential health benefits, including antioxidants and anti-inflammatory agents. Pressurized liquid extraction (PLE) stands out as a promising technique for effectively extracting valuable compounds from natural sources. In this study, we aimed to optimize PLE parameters, such as temperature, extraction duration, and pressure, to maximize bioactive compound (polyphenols, flavonoids, and ascorbic acid) yield from M. oleifera leaves and evaluate their antioxidant and anti-inflammatory activities. According to the outcomes of this research, the maximum achieved total polyphenol content was 24.10 mg gallic acid equivalents (GAE)/g of dry weight (dw), and the total flavonoid content was increased up to 19.89 mg rutin equivalents (RtE)/g dw. Moreover, after HPLC-DAD analysis, neochlorogenic and chlorogenic acids, catechin and epicatechin, rutin, and narirutin were identified and quantified. As far as the optimum ascorbic acid content is concerned, it was found to be 4.77 mg/g dw. The antioxidant activity was evaluated by three different methods: ferric reducing antioxidant power (FRAP), the DPPH method, and the anti-hydrogen peroxide activity (AHPA) method, resulting in 124.29 µmol ascorbic acid equivalent (AAE)/g dw, 131.28 µmol AAE/g dw, and 229.38 µmol AAE/g dw values, respectively. Lastly, the albumin denaturation inhibition was found to be 37.54%. These findings underscore the potential of PLE as an efficient extraction method for preparing extracts from M. oleifera leaves with the maximum content of bioactive compounds.


Subject(s)
Antioxidants , Moringa oleifera , Plant Extracts , Plant Leaves , Moringa oleifera/chemistry , Plant Leaves/chemistry , Antioxidants/pharmacology , Antioxidants/chemistry , Antioxidants/isolation & purification , Plant Extracts/pharmacology , Plant Extracts/chemistry , Flavonoids/isolation & purification , Flavonoids/analysis , Flavonoids/chemistry , Flavonoids/pharmacology , Polyphenols/isolation & purification , Polyphenols/pharmacology , Polyphenols/analysis , Polyphenols/chemistry , Ascorbic Acid/pharmacology , Anti-Inflammatory Agents/pharmacology , Anti-Inflammatory Agents/chemistry , Anti-Inflammatory Agents/isolation & purification , Chromatography, High Pressure Liquid/methods , Pressure , Liquid-Liquid Extraction/methods , Phytochemicals/chemistry , Phytochemicals/pharmacology , Phytochemicals/isolation & purification
13.
Sensors (Basel) ; 24(9)2024 Apr 23.
Article in English | MEDLINE | ID: mdl-38732781

ABSTRACT

INTRODUCTION: Diabetic foot ulcers (DFU) are a devastating complication of diabetes. There are numerous challenges with preventing diabetic foot complications and barriers to achieving the care processes suggested in established foot care guidelines. Multi-faceted digital health solutions, which combine multimodal sensing, patient-facing biofeedback, and remote patient monitoring (RPM), show promise in improving our ability to understand, prevent, and manage DFUs. METHODS: Patients with a history of diabetic plantar foot ulcers were enrolled in a prospective cohort study and equipped with custom sensory insoles to track plantar pressure, plantar temperature, step count, and adherence data. Sensory insole data enabled patient-facing biofeedback to cue active plantar offloading in response to sustained high plantar pressures, and RPM assessments in response to data trends of concern in plantar pressure, plantar temperature, or sensory insole adherence. Three non-consecutive case participants that ultimately presented with pre-ulcerative lesions (a callus and/or erythematous area on the plantar surface of the foot) during the study were selected for this case series. RESULTS: Across three illustrative patients, continuous plantar pressure monitoring demonstrated promise for empowering both the patient and provider with information for data-driven management of pressure offloading treatments. CONCLUSION: Multi-faceted digital health solutions can naturally enable and reinforce the integrative foot care guidelines. Multi-modal sensing across multiple physiologic domains supports the monitoring of foot health at various stages along the DFU pathogenesis pathway. Furthermore, digital health solutions equipped with remote patient monitoring unlock new opportunities for personalizing treatments, providing periodic self-care reinforcement, and encouraging patient engagement-key tools for improving patient adherence to their diabetic foot care plan.


Subject(s)
Diabetic Foot , Humans , Diabetic Foot/therapy , Male , Female , Middle Aged , Aged , Prospective Studies , Pressure , Monitoring, Physiologic/methods , Digital Health
14.
Sensors (Basel) ; 24(9)2024 May 06.
Article in English | MEDLINE | ID: mdl-38733050

ABSTRACT

Gait phase monitoring wearable sensors play a crucial role in assessing both health and athletic performance, offering valuable insights into an individual's gait pattern. In this study, we introduced a simple and cost-effective capacitive gait sensor manufacturing approach, utilizing a micropatterned polydimethylsiloxane dielectric layer placed between screen-printed silver electrodes. The sensor demonstrated inherent stretchability and durability, even when the electrode was bent at a 45-degree angle, it maintained an electrode resistance of approximately 3 Ω. This feature is particularly advantageous for gait monitoring applications. Furthermore, the fabricated flexible capacitive pressure sensor exhibited higher sensitivity and linearity at both low and high pressure and displayed very good stability. Notably, the sensors demonstrated rapid response and recovery times for both under low and high pressure. To further explore the capabilities of these new sensors, they were successfully tested as insole-type pressure sensors for real-time gait signal monitoring. The sensors displayed a well-balanced combination of sensitivity and response time, making them well-suited for gait analysis. Beyond gait analysis, the proposed sensor holds the potential for a wide range of applications within biomedical, sports, and commercial systems where soft and conformable sensors are preferred.


Subject(s)
Gait , Pressure , Wearable Electronic Devices , Wireless Technology , Humans , Gait/physiology , Wireless Technology/instrumentation , Gait Analysis/methods , Gait Analysis/instrumentation , Electrodes , Shoes , Equipment Design
15.
Crit Rev Biomed Eng ; 52(4): 17-28, 2024.
Article in English | MEDLINE | ID: mdl-38780103

ABSTRACT

In this study, we examine the behavior of articular cartilage equilibrated in a salt (NaCl) solution during non-Newtonian fluid flow that follows an Ostwald-de Waele model. A linearly elastic and isotropic rectangular strip of cartilage is considered for analysis. A continuum theory of mixtures has been employed to develop a coupled system of partial differential equations for the solid displacement and the fluid pressure by considering the important factor of the ion concentration by assuming the cartilage as a deformable porous media. The coupled system of partial differential equations is solved using the numerical method named method of lines. In most cases, shear-thinning fluid is compared to the shear-thickening fluid to magnify the difference. Graphical results show that shear-thickening fluids bring more solid deformation and shows less fluid pressure in comparison to the shear-thinning fluids.


Subject(s)
Cartilage, Articular , Pressure , Cartilage, Articular/physiology , Models, Biological , Humans , Ions , Animals , Rheology/methods , Elasticity , Sodium Chloride/chemistry , Viscosity , Porosity
16.
J Agric Food Chem ; 72(20): 11629-11639, 2024 May 22.
Article in English | MEDLINE | ID: mdl-38739462

ABSTRACT

Blueberries (Vaccinium section Cyanococcus) have a wealth of bioactive compounds, including anthocyanins and other antioxidants, that offer significant health benefits. Preserving these compounds and maintaining the sensory and nutritional qualities of blueberry products such as juice during cold market storage is critical to meet consumer expectations for nutritious, safe, and minimally processed food. In this study, we compared the effects of two preservation processing techniques, high-temperature short-time (HTST) and continuous flow high-pressure homogenization (CFHPH), on blueberry juice quality during storage at 4 °C. Our findings revealed that inlet temperature (Tin) of CFHPH processing at 4 °C favored anthocyanin retention, whereas Tin at 22 °C favored ascorbic acid retention. After 45 days of storage, CFHPH (300 MPa, 1.5 L/min, 4 °C) juice retained up to 54% more anthocyanins compared to control at 0 day. In contrast, HTST treatment (95 °C, 15 s) initially increased anthocyanin concentrations but led to their subsequent degradation over time, while also significantly degrading ascorbic acid. Furthermore, CFHPH (300 MPa, 4 °C) juice had significantly lower polyphenol oxidase activity (>80% less than control), contributing to the overall quality of the juice. This innovative processing technique has the potential to improve commercial blueberry juice, and help meet the rising demand for healthy and appealing food choices.


Subject(s)
Anthocyanins , Ascorbic Acid , Blueberry Plants , Cold Temperature , Food Storage , Fruit and Vegetable Juices , Fruit , Anthocyanins/chemistry , Anthocyanins/analysis , Blueberry Plants/chemistry , Ascorbic Acid/analysis , Ascorbic Acid/chemistry , Fruit and Vegetable Juices/analysis , Fruit/chemistry , Pressure , Food Preservation/methods , Food Preservation/instrumentation , Food Handling/methods , Food Handling/instrumentation , Antioxidants/chemistry , Antioxidants/analysis
17.
Sci Rep ; 14(1): 11084, 2024 05 15.
Article in English | MEDLINE | ID: mdl-38744916

ABSTRACT

In order to solve the difficult portability problem of traditional non-invasive sleeping posture recognition algorithms arising from the production cost and computational cost, this paper proposes a sleeping posture recognition model focusing on human body structural feature extraction and integration of feature space and algorithms based on a specific air-spring mattress structure, called SPR-DE (SPR-DE is the Sleep Posture Recognition-Data Ensemble acronym form). The model combines SMR (SMR stands for Principle of Spearman Maximal Relevance) with horizontal and vertical division based on the barometric pressure signals in the human body's backbone region to reconstruct the raw pressure data into strongly correlated non-image features of the sleep postures in different parts and directions and construct the feature set. Finally, the recognit-ion of the two sleep postures is accomplished using the AdaBoost-SVM integrated classifier. SPR-DE is compared with the base and integrated classifiers to verify its performance. The experimental results show that the amount of significant features helps the algorithm to classify different sleeping patterns more accurately, and the f1 score of the SPR-DE model determined by the comparison experiments is 0.998, and the accuracy can reach 99.9%. Compared with other models, the accuracy is improved by 2.9% ~ 7.7%, and the f1-score is improved by 0.029 ~ 0.076. Therefore, it is concluded that the SMR feature extraction strategy in the SPR-DE model and the AdaBoost-SVM can achieve high accuracy and strong robustness in the task of sleep posture recognition in a small area, low-density air-pressure mattress, taking into account the comfort of the mattress structural design and the sleep posture recognition, integrated with the mattress adaptive adjustment system.


Subject(s)
Algorithms , Beds , Posture , Sleep , Humans , Posture/physiology , Sleep/physiology , Pressure , Male , Adult
18.
PLoS One ; 19(5): e0303325, 2024.
Article in English | MEDLINE | ID: mdl-38748668

ABSTRACT

Since the 19th century, underwater explosions have posed a significant threat to service members. While there have been attempts to establish injury criteria for the most vulnerable organs, namely the lungs, existing criteria are highly variable due to insufficient human data and the corresponding inability to understand the underlying injury mechanisms. This study presents an experimental characterization of isolated human lung dynamics during simulated exposure to underwater shock waves. We found that the large acoustic impedance at the surface of the lung severely attenuated transmission of the shock wave into the lungs. However, the shock wave initiated large bulk pressure-volume cycles that are distinct from the response of the solid organs under similar loading. These pressure-volume cycles are due to compression of the contained gas, which we modeled with the Rayleigh-Plesset equation. The extent of these lung dynamics was dependent on physical confinement, which in real underwater blast conditions is influenced by factors such as rib cage properties and donned equipment. Findings demonstrate a potential causal mechanism for implosion injuries, which has significant implications for the understanding of primary blast lung injury due to underwater blast exposures.


Subject(s)
Blast Injuries , Lung , Humans , Lung/physiology , Blast Injuries/etiology , Explosions , Lung Injury/etiology , Male , Pressure , High-Energy Shock Waves/adverse effects
19.
Opt Lett ; 49(9): 2341-2344, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38691714

ABSTRACT

In the fields of biomedicine and microfluidics, the non-contact capture, manipulation, and spin of micro-particles hold great importance. In this study, we propose a programmable non-contact manipulation technique that utilizes photoacoustic effect to spin and transport living shrimp eggs. By directing a modulated pulsed laser toward a liquid-covered stainless-steel membrane, we can excite patterned Lamb waves within the membrane. These Lamb waves occur at the interface between the membrane and the liquid, enabling the manipulation of nearby particles. Experimental results demonstrate the successful capture, spin, and transport of shrimp eggs in diameter of 220 µm over a distance of about 5 mm. Calculations indicate that the acoustic radiation force and torque generated by our photoacoustic manipulation system are more than 299.5 nN and 41.0 nN·mm, respectively. The system surpasses traditional optical tweezers in terms of force and traditional acoustic tweezers in terms of flexibility. Consequently, this non-contact manipulation system significantly expands the possibilities for applications in various fields, including embryo screening, cell manipulation, and microfluidics.


Subject(s)
Ovum , Photoacoustic Techniques , Animals , Photoacoustic Techniques/methods , Pressure , Optical Tweezers , Penaeidae
20.
Med Eng Phys ; 127: 104168, 2024 May.
Article in English | MEDLINE | ID: mdl-38692764

ABSTRACT

Skin color observation provides a simple and non-invasive method to estimate the health status of patients. Capillary Refill Time (CRT) is widely used as an indicator of pathophysiological conditions, especially in emergency patients. While the measurement of CRT is easy to perform, its evaluation is highly subjective. This study proposes a method to aid quantified CRT measurement using an RGB camera. The procedure consists in applying finger compression to the forearm, and the CRT is calculated based on the skin color change after the pressure release. We estimate compression applied by a finger from its fingernail color change during compression. Our study shows a step towards camera-based quantitative CRT for untrained individuals.


Subject(s)
Capillaries , Fingers , Fingers/blood supply , Fingers/physiology , Humans , Capillaries/physiology , Capillaries/diagnostic imaging , Time Factors , Pressure , Male , Adult , Mechanical Phenomena , Female
SELECTION OF CITATIONS
SEARCH DETAIL
...